Navien- Tankless Water Heater Error Codes
| 
                                Error Code                             | 
                                Description                             | 
|---|---|
| Error Code E03 | Ignition Failure- Ensure that the main gas supply valve is open | 
| Error Code E04 | False Flame Detection Ensure that the electrical cord is properly grounded | 
| Error Code E12 | 
Flame Loss
 
 | 
| Error Code E16 | 
Overheating of heat exchanger
 
 | 
| Error Code E30 | Abnormal exhaust temperature. Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E46 | Abnormal Operation: Limit Control Contact Technical Support at 1-800-519-8794 or a Licensed Navien Technician | 
| Error Code E47 | Abnormal operation: Exhaust Thermostat Contact Technical Support at 1-800-519-8794 or a Licensed Navien Technician | 
| Error Code E60 | Error Code E060: Abnormal Operation: Dual Venturi Contact Technical Support at 1-800-519-8794 or a Licensed Navien Technician | 
| Error Code E109 | 
Abnormal Operation: Fan Motor
 
 | 
| Error Code E110 | 
Abnormal Air Pressure
 
 | 
| Error Code E205 | Heating supply thermistor open or short circuit Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E218 | Heating return thermistor open or short circuit Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E351 | Abnormal Auto feeder valve (make-up water) Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E352 | High water pressure Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E353 | Abnormal operation: water pressure sensor Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E407 | Hot water outlet thermistor open or short circuit Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E421 | Cold water inlet thermistor open or short circuit Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E439 | Abnormal operation: flow sensor Reset the boiler from the front panel. | 
| Error Code E515 | Abnormal operation: PCB Ensure that the electrical cord is properly grounded. Reset the boiler from the front panel. | 
| Error Code E517 | Abnormal operation: DIP switch setting Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E594 | Abnormal operation: EEPROM Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E615 | Abnormal operation: input and memory Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E736 | Abnormal operation: cascade communication Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
| Error Code E740 | 
Abnormal operation: outdoor temperature sensor (appears only when the outdoor reset curve is enabled).  Ensure that the outdoor reset curve is configured properly. Check the outdoor temperature sensor wiring connection. | 
| Error Code E777 | Abnormal operation: LWCO Check the LWCO wiring connection Ensure that the system water level is appropriate. Add make-up water to the system if necessary. | 
| Error Code E782 | Abnormal operation: main panel communication Call or Text Blue Conservation’s trained Navien specialists at 484-469-0718. | 
 
															 
															 
															