| Noritz | Error Code 05 | Service WarningIt’s time to schedule service. Do not reset the error code prior to the service or the water heater may prematurely fail. |
| Noritz | Error Code 10 | Power Drop or Gas Combustion continues after the unit is shut off Look for foreign materials (i.e., oil or grease) on the burner that are still burning after gas combustion stops. To reset the code, turn the unit off and then on. |
| Noritz | Error Code 11 | Ignition failureCheck the gas pressure for correct values. Look for any obstructions in the vents as the fresh air supply might be being blocked. Remove any foreign materials from the ignition rod. Confirm there is no loose wiring in the ignition. |
| Noritz | Error Code 12 | The tankless unit has a weak flame and the water is not being properly heated Confirm that there is enough airflow for proper gas combustion. Check that the flame rod/sensor is not covered by debris. Clean or replace if necessary. |
| Noritz | Error Code 14 | The thermal fuse has failedReplace the thermal fuse. Confirm that the unit has no airflow restrictions and gas has proper combustion. Check water quality, as hard water or sediment can cause the heat exchanger to become clogged. Flush the heat exchanger if necessary. |
| Noritz | Error Code 16 | Water temperature is too highSince this is most often caused by hard water or scale buildup, a descaling procedure should be performed. To reset the code afterward, unplug the water heater for 20 seconds and then plug it back in. |
| Noritz | Error Code 20 | High-limit switch has been activatedCheck the high-limit switch and replace if necessary. Otherwise, perform the descaling procedure. |
| Noritz | Error Code 29 | Water level in the neutralizer is not properly draining, causing the water to exceed the correct levelMake sure the condensate drain line is properly routed and unobstructed. Confirm condensate piping is the correct size and properly sloped. |
| Noritz | Error Code 31 | Inlet (cold water) thermistor failureReplace inlet thermistor. |
| Noritz | Error Code 32 | Outlet (hot water) thermistor failureReplace outlet thermistor. |
| Noritz | Error Code 33 | Heat exchanger thermistor failureReplace the heat exchanger thermistor. |
| Noritz | Error Code 45 | Water leakClose the water inlet valve and call for service if you notice a leak. If there is no visible leak, unplug the unit for 30 seconds to reset it and see if the code clears itself. |
| Noritz | Error Code 59 | Low gas BTU input causing combustion problemsConfirm correct gas pressure as well as gas settings for elevation where it is installed. Make sure enough airflow is getting to the combustion chamber by removing any noticeable blockage of the vents. Clean fan motor and burner chamber. |
| Noritz | Error Code 61 | Fan motor failureCheck voltage coming to the fan motor. Replace fan motor or circuit board if necessary. |
| Noritz | Error Code 65 | Main flow control valve failureCheck for blockage and replace the main flow control valve if necessary. |
| Noritz | Error Code 66 | Bypass flow control valve failureCheck for blockage and replace the bypass flow control valve if necessary. |
| Noritz | Error Code 67 | AGM ( Air Gas Mixer) abnormalityTurn the unit off then on. If the code reappears, the air gas mixer will likely need to be replaced. |
| Noritz | Error Code 70 | Circuit board failureReplace circuit board. |
| Noritz | Error Code 71 | Abnormality in gas valve drive circuitConfirm correct voltage. This error code is often seen when a unit is connected to a generator or battery backup or if there is another type of voltage fluctuation. Install a power surge protector if necessary. |
| Noritz | Error Code 72 | Flame rod detection abnormalityConfirm that the water heater is properly grounded. Check for a damaged circuit board, flame detection circuit, or wires, and replace if necessary. |
| Noritz | Error Code 73 | Improper circuit board settingMost likely a jumper connection or dip switch was changed on the circuit board while under power, or the circuit board was improperly programmed. Unplug the unit for 30 seconds and plug back in. If the error code still shows up, call or text Blue Conservation’s trained Noritz specialists at 484-469-0718 |
| Noritz | Error Code 90 | and 91Gas combustion abnormalityCheck airflow obstruction and improper gas burning. Confirm correct air/fuel mixture and gas pressure. Once fixed, reset the unit by unplugging for 30 seconds. |
| Noritz | Error Code 92 | and 93Neutralizer is at the end of its life cycleReplace neutralizer and reset burner timer. |
| Noritz | Error Code 99 | Abnormal CombustionCall or text Blue Conservation’s trained Noritz specialists at 484-469-0718. |
| Noritz | Error Code 760 | Remote controller problemCheck for loose wires and confirm only one remote is connected to the water heater. Unplug the unit for 30 seconds to reset. |
| Noritz | Error Code 902 | Abnormal Combustion Have a professional check the gas supply pressure. Call or text Blue Conservation’s trained Noritz specialists at 484-469-0718. |
| Noritz | Error Code 903 | and 908Abnormal combustionConfirm nothing is obstructing the intake or exhaust pipe. |
| Noritz | Error Code 941 | and 942 Exhaust temperature is too highCheck for and clear any air blockages and reset unit. If that doesn’t work, call or text Blue Conservation’s trained Noritz specialists at 484-469-0718. |
| Noritz | Error Code F76 | Communication error between two tankless water heaters using Quick Connect cordConfirm that only one remote control is hooked up when multiple units are connected together. Unplug the unit for 30 seconds and plug back in to reset it. |
| Noritz | Error Code CF1, | |
| Noritz | Error Code CF2, | |
| Noritz | Error Code CF3, | |
| Noritz | Error Code CF4 | The unit detects scale buildup in the Heat ExchangerFlush the heat exchanger in accordance with the process in the owner’s manual. |
| Noritz | Error Code CF1, | |
| Noritz | Error Code CF2, | |
| Noritz | Error Code CF3, | |
| Noritz | Error Code CF4, | |
| Noritz | Error Code CF5, | |
| Noritz | Error Code CF6, | |
| Noritz | Error Code CF7, | Error Code, CF8, |
| Noritz | Error Code CF9, | |
| Noritz | Error Code CFA, | |
| Noritz | Error Code CFb, | |
| Noritz | Error Code CFC, | |
| Noritz | Error Code CFd, | |
| Noritz | Error Code CFE, | |
| Noritz | Error Code CFF | The unit detects scale buildup in the heat exchanger many times and the unit is lockedCall or text Blue Conservation’s trained Noritz specialists at 484-469-0718 and see “How to Fix: Flush the Heat Exchanger” in accordance with the process in the owner’s manual. |